pH
Meter
Brand : EcoScan
Country: Singapore
¡@
|
Product
Features
|
:: |
Multi-Point
Calibration
(up
to 3
points)
with
Auto-Buffer
Recognition
-
choice
of
USA,
NIST
or
pure
water
buffer
standards
with
¡Ó0.01
pH
accuracy |
|
¡@ |
¡@ |
|
:: |
Automatic
Temperature
Compensation
(ATC)
for
the
highest
accuracy
under
fluctuating
temperatures
|
|
¡@ |
¡@ |
|
:: |
Hold
Function
momentarily
freezes
reading
for
easy
viewing
and
recording
|
|
¡@ |
¡@ |
|
:: |
Auto-Power
Off
saves
battery
power
after
non-use
|
|
¡@ |
¡@ |
|
:: |
Self-Diagnostic
with
message
codes
for
easy
troubleshooting
|
|
¡@ |
¡@ |
|
:: |
Large
Custom
LCD
provides
optimum
viewing
even
at a
distance
|
|
¡@ |
¡@ |
|
:: |
Protective
Rubber
Boot
shields
meter
from
accidental
knocks
and
features
a
sturdy
built-in
stand
for
easy
bench-top
operation
|
|
¡@ |
¡@ |
|
:: |
Rugged
Carrying
Case
(Optional)
provides
handy
on-site
meter
calibration
and
measurement
|
¡@ |
¡@
Applications
Water
Quality Testing:
For analyzing water
in pools and spas,
lithographic
processes, boiler
and cooling tower
water analysis and
all types of quality
assurance and water
quality testing.
Environmental/Agricultural:
Use in ecology
studies, aquariums,
aquaculture and
nutrients levels in
hydroponics.
Educational:
Ideal for quick,
accurate checks in
laboratories and
schools.
Specifications
|
Product
Specification |
Description |
|
pH
Range |
0.00 to
14.00 pH |
|
Resolution &
Accuracy |
0.01 pH & ¡Ó
0.01 pH |
|
Temperature
Range |
0 to 100.0
¢XC |
|
Resolution &
Accuracy |
0.1 ¢XC & ¡Ó
0.5 ¢XC |
|
mV
Range |
Not
available |
|
Resolution &
Accuracy |
- |
|
Temperature
Compensation |
Automatic /
Manual (0 to
100 ¢XC) |
|
No.
of
Calibration
Points |
Up to 3
points |
|
pH
Buffer
Options |
pH 4.01,
7.00, 10.01
(USA)
pH 4.01,
6.86, 9.18 (NIST)
pH 4.10,
6.97 (Pure
water) |
|
Special
Functions |
Auto
Power-Off
after 17
minutes;
Hold &
Self-diagnostic
messages |
|
Power |
4 'AAA' x
1.4V
batteries |
Order Information
|
Order No.
|
Item |
|
EC-PH5/02K |
EcoScan pH 5
Palmtop pH
Meter with
pH
electrode,
temperature
probe &
EcoScan pH
carry kit
set (EC-ECOPH-KIT) |
|
EC-ECOPH-KIT |
EcoScan pH
Carry Kit
Set ¡V
EcoScan
Plastic
Carry Case
comprises: 1
x pH 4.01,
pH 7.00, pH
10.01 buffer
solutions
(60 ml each)
and 1 x
empty
rinse water
bottle |
Back to Top
¡@
|
|
|
|
|
Brand : CyberScan
Country: Singapore
¡@
¡@
|
Product Features
| :: |
5-point Push-Button
Calibration with Auto-Buffer Recognition for quick
calibration with no calibration mistakes |
| ¡@ |
¡@ |
| :: |
Choice of pH Buffer sets: USA, NIST,
DIN or Low Ionic to cater wider applications |
| ¡@ |
¡@ |
| :: |
Automatic Temperature Compensation (ATC)
for the highest accuracy under fluctuating
temperatures |
| ¡@ |
¡@ |
| :: |
Stores/ Recalls up to 100 Data Sets
with temperature readings |
| ¡@ |
¡@ |
| :: |
RS232 output with PC-based
Complimentary Data Acquisition Software (for pH110)
helps organize data to import into most popular
spreadsheet programs for report generation |
| ¡@ |
¡@ |
| :: |
Recall Electrode Slope, Electrode
Offset Value and Previous Calibration Values for
easy reference |
| ¡@ |
¡@ |
| :: |
Stability Indicator prompts whenever
reading stabilizes |
| ¡@ |
¡@ |
| :: |
Hold Function momentarily freeze
reading for easy viewing and recording |
| ¡@ |
¡@ |
| :: |
Auto-Power Off conserves battery
power and save money |
| ¡@ |
¡@ |
| :: |
Self-Diagnostic with message codes
for easy troubleshooting
|
| ¡@ |
¡@ |
| :: |
Large, Easy-to-Read Custom LCD
Display with simultaneous readings provides optimum
viewing with user-friendly icons |
| ¡@ |
¡@ |
| :: |
Power with batteries or optional AC
adapter for use in the field or at bench-top with
built-in stand |
| ¡@ |
¡@ |
| :: |
Rugged Carrying Case (Optional)
provides handy on-site meter calibration and
measurement |
¡@ |
¡@
|
|
|
|
Standard CyberScan carrying
kit set
|
|
Applications
Industrial: For checks in water
conditioning plants, conditioning plants, cooling towers, food
processing water testing, printing and chemical industries, and
water/wastewater treatment. Use with ORP electrode to monitor
plating operations, and other redox measurements.
Environmental/Agricultural: Use in
ecology studies, aquariums, and hydroponics.
Educational: Ideal for quick,
accurate routine pH checks in laboratories and schools.
¡@
Specifications
|
Product
Specification |
Description |
| pH Range |
-2.00 to 16.00 pH |
|
Resolution & Accuracy |
0.01 & ¡Ó0.01 pH |
| mV Range |
¡Ó199.9 mV
(extended) & ¡Ó1999 mV |
|
Resolution & Accuracy |
0.1 mV & ¡Ó0.2 mV (within ¡Ó199.9 mV);
1 mV & ¡Ó2 mV (beyond ¡Ó200 mV) |
| Temperature Range |
-10.0 to 110.0 ¢XC |
|
Resolution & Accuracy |
0.1 ¢XC & ¡Ó0.5 ¢XC |
| Temperature Compensation |
Automatic / Manual
(0 to 100 ¢XC) |
|
No. of Calibration Points |
Up to 5 points |
| pH Buffer
Options |
USA,
NIST |
| Auto-Hold |
No |
| Memory |
50 data sets |
| Output |
No |
| pH Slope & Offset
Display |
Yes |
| Special
Functions |
Stability
Indicator; Self-diagnostic;
Hold & Auto-Power Off after 20 minutes |
| Power |
4 'AAA' x 1.4V
batteries or 9VDC power adapter |
Order Information
|
Order No.
|
Item |
| EC-PH11/02K |
CyberScan pH 11 Portable pH/mV Meter with pH electrode,
temperature probe, 2 electrode holders & CyberScan pH carry
kit set (EC-PHWP-KIT) |
| EC-PHWP-KIT |
CyberScan pH
Carry Kit Set ¡V CyberScan Plastic Carry Case comprises 1 x
pH 4.01, pH 7.00, pH 10.01 buffer solutions (60 ml each) and
1 x empty
rinse water bottle |
Back to Top
¡@
|
Product Features
| :: |
Low Cost Plus High
Performance - offers laboratory-quality readings for
a very economical cost |
| ¡@ |
¡@ |
| :: |
Multi-Point Push-Button Calibration
(up to 3 points) with Auto-Buffer Recognition -
choice of USA and NIST pH buffer standards for quick
calibration with no calibration mistakes |
| ¡@ |
¡@ |
| :: |
Direct Ion Concentration measurement
with use of many Ion Selective Electrodes (for Ion
510 model only) |
| ¡@ |
¡@ |
| :: |
Expanded Memory stores and recalls
up to 50 data sets |
| ¡@ |
¡@ |
| :: |
Analogue Recorder for external chart
recording devices |
| ¡@ |
¡@ |
| :: |
Viewing of Electrode Characteristics
- electrode slope and offset value to verify
electrode performance |
| ¡@ |
¡@ |
| :: |
Automatic Temperature Compensation (ATC)
for optimum accuracy under fluctuating temperatures
|
| ¡@ |
¡@ |
| :: |
Hold Function momentarily freezes
reading for easy viewing and recording |
| ¡@ |
¡@ |
| :: |
Stability Indicator prompts whenever
reading stabilizes |
| ¡@ |
¡@ |
| :: |
Self-Diagnostic with message codes
for easy troubleshooting
|
| ¡@ |
¡@ |
| :: |
Large, Easy-to-Read Custom LCD
Display with simultaneous readings provides optimum
viewing with user-friendly icons |
| ¡@ |
¡@ |
| :: |
Slide-out Instruction Card for quick
reference |
| ¡@ |
¡@ |
| :: |
Detachable Electrode Stand organizes
multiple electrodes neatly and holds them firmly in
place |
¡@ |
¡@
|
|
|
¡@
|
|
Dual-display LCD
|
Quick reference slide-out
instruction card
|
¡@
|
Applications
General: Ideal for all kinds of
water quality, chemical testing in the laboratory and
soil/fertilizer testing. Suitable for most ASTM and EPA test
procedures. Great for R&D and QC applications in chemical industries
and related fields.
Educational: Perfect for students at
all levels; suitable for all types of chemistry labs and ecology
studies.
Water Quality Testing: Use for quick
fluoride level checks and tests on priority pollutants and
contamination.
Specifications
|
Product
Specification |
Description |
| pH Range |
0.00 to 14.00 pH |
|
Resolution & Accuracy |
0.01 & ¡Ó0.01 pH |
| Ion Concentration Range |
Not available
|
|
Resolution & Accuracy |
- |
| mV Range |
¡Ó199.9 mV; ¡Ó1999
mV |
|
Resolution & Accuracy |
0.1 mV & ¡Ó0.2 mV (within ¡Ó199.9 mV);
1 mV & ¡Ó2 mV (beyond ¡Ó200 mV) |
| Temperature Range |
0.0 to 100.0 ¢XC |
|
Resolution & Accuracy |
0.1 ¢XC & ¡Ó0.3 ¢XC |
| No. of Calibration Points |
Up to 3 points |
|
pH Buffer Options |
USA (pH 4.01, 7.00, 10.01);
NIST (pH 4.01, 6.86, 9.18) |
| Memory |
50
Data Sets |
|
Temperature Compensation |
Automatic / Manual (0 to 100 ¢XC) |
| Recorder Output |
Yes |
|
Special Functions |
Stability Indicator; Self-diagnostic;
Hold & pH Slope/Offset Display |
| Power |
9VDC, using AC
adapters 110VAC or 220VAC, 50/60 Hz |
Order Information
|
Order No.
|
VAC |
Item |
| EC-PH510/11S |
110 |
CyberScan pH 510 Bench pH/mV Meter with ATC probe, integral
electrode holder & power adapter |
| EC-PH510/21S |
220 |
CyberScan pH 510
Bench pH/mV Meter with ATC probe, integral electrode holder
& power adapter |
¡@
Back to Top
¡@
|
|