Infusion Pumps

Model 100

Model 101

Model 200

Model 220

Model 250

¡@

Infusion / Withdrawal Pumps

Model 210

Model 230

Model 310

¡@

Push - Pull Pump

Model 120

Model 270

Model 260

¡@

Micro Emulsion Making Pump

Model 330

¡@

¡@

¡@

¡@

Model 100

A basic single syringe, infusion pump which combines precision with simplicity.

Features

  • Single syringe 10 ml to 60 ml, any manufacturer
  • Simple menu-driven setup:
    • select syringe size  from displayed table
    • set dispense volume
    • set dispense flow rate
  • Easy to read bright, backlight display
  • Dispense volume displayed and has automatic shutoff at completion
  • Volume and flow rate units (ml/hr or ml/hr) are selected automatically based on syringe size
  • Last settings stored in permanent memory
  • Button release of drive nut for easy syringe installation
  • Choice of run / stop after a power interruption

Specifications

Pump Type Infusion
Max. No. of  Syringes One
Syringe Size 10 ml to 60 ml
Dimensions 9 x 6 x 5 in.
23 x 15 x 12 cm
Weight 4.5 lb (2 kg)
Linear Force 20 lb (9 kg) min.

Advance Per Microstep

0.529 micron (1/2 step)
Max Step Rate (1/2 Step) 400 steps/sec
Min Step Rate 1 step / 30 sec.
Accuracy .¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.1 ml/h

126 ml/h

25 ml

0.2 ml /h

318 ml/h

50 ml

0.2 ml/h

625 ml/h

100 ml

1.0 ml /h

1274 ml/h

250 ml

2.0 ml/h

3164 ml/h

500 ml

3.0 ml /h

6359 ml/h

1 ml

0.01 ml/h

13.2 ml/h

2.5  ml

0.02  ml/h

31.7 ml/h

3 ml

0.03 ml/h

44.9 ml/h

5 ml

0.03  ml/h

87.0 ml/h

10 ml

0.1 ml/h

127 ml/h

20 ml

0.1  ml/h

219 ml/h

30 ml

0.1  ml/h

282 ml/h

60 ml

0.2  ml/h

519 ml/h

back to top


Model 101

Our dual-syringe infusion pump is ideal for microdialysis and similar applications which require virtually pulseless flow at very low flow rates

Features

  • Hold 2 syringes, 10 µl to 10 ml each or, a single syringe up to 60 ml
  • Simple menu prompt setup:
    • select syringe size  from displayed table
    • set dispense volume
    • set dispense flow rate
  • Easy to read bright, backlight display
  • Dispense volume displayed and has automatic shutoff at completion
  • Volume and flow rate units (ml/min or ml/min) are selected automatically based on syringe size
  • Last settings stored in permanent memory
  • Button release of drive nut for easy syringe installation
  • Choice of run / stop after a power interruption

Specifications

Pump Type Infusion
Max. No. of  Syringes Two (up to 10 ml)
Syringe Size 10ul - 10ml ( two syr)
10ul - 60ml ( one syr)
Dimensions 9 x 6 x 5 in.
23 x 15 x 12 cm
Weight 4.5 lb (2 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep    

0.088 micron (1/2 step)
Max Step Rate (1/2 Step) 400 steps/sec
Min Step Rate 1 step / 30 sec.
Accuracy ¡Ó  < 1%
Reproducibility ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

0.382 ml/min

25 ml

0.001 ml/h

0.884 ml/min

50 ml

0.001 ml/h

1.762 ml/min

100 ml

0.001 ml/h

3.542 ml/min

250 ml

0.01 ml/h

8.78 ml/min

500 ml

0.01 ml/h

17.65 ml/min

1 ml

0.1 ml/h

35.2 ml/min

3  ml

0.1 ml/h

122.5 ml/min

5 ml

0.1 ml/h

176.2 ml/min

10 ml

0.001  ml/h

0.351 ml/min

20 ml

0.001 ml/h

0.602ml/min

30 ml

0.001  ml/h

0.773 ml/min

60 ml

0.001  ml/h

1.175 ml/min

back to top


Model 200

Two-Syringe Infusion Pump  This feature-laden two-syringe infusion pump combines a broad speed range and holds a wide range of syringe sizes to meet the requirements of virtually any laboratory application

Features

  • Holds one or two syringes, 10 ml to 140 ml each
  • Backlit LCD display
  • Knob locks/unlocks drive block for effortless, drag-free manual adjustment
  • Simple menu-driven setup:
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
  • Continuous dispense volume display
  • Preset volume control and automatic shut-off
  • Choice of unit selection
  • Settings can be reviewed or changed during operation
  • Stall detection
  • Last settings stored in permanent memory
  • Built-in RS232C interface for computer "daisy chaining" up to 100 pumps
  • TTL interface for foot switch, timer, relay control, outputs for run indicator, valve control
  • Optional multi-step keypad programmable feature (Model 200P)

Specifications

Pump Type Infusion
Max. No. of  Syringes Two
Syringe Size 10 ml to 140 ml
Dimensions 11 x 9 x 5.5 in.
28 x 23 x 15 cm
Weight 9 lb (4 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep

0.165 micron (1/16 step)
Max Step Rate (1/2 Step) 1600/sec
Min Step Rate 1 step 1/100 sec
Accuracy ¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

22.98 ml/min

25 ml

0.001 ml /h

60.68 ml/min

50 ml

0.001 ml/h

105.8 ml/min

100 ml

0.001 ml /h

212.6 ml/min

250 ml

0.001 ml/h

527.6 ml/min

500 ml

0.001 ml /h

1.06 ml/min

1 ml

0.001 ml/h

2.203 ml/min

3  ml

0.001 ml /h

7.36 ml/min

5 ml

0.001 ml/h

14.33 ml/min

10 ml

0.001 ml /h

20.91 ml/min

20 ml

0.001 ml/h

36.19 ml/min

30 ml

0.001 ml /h

46.49 ml/min

60 ml

0.001 ml/h

86 ml/min

140 ml

0.001 ml /h

145 ml/min

back to top


Model 220

Model 220 Multi-Syringe Infusion Pump Ideal for applications requiring multiple syringes, the Model 220.  Each has been modified to hold up to 10 syringes.

Features

  • Multiple syringe holder:
    • One to ten syringes, 10 ml - 10 ml
    • One to six syringes, 20 ml - 60 ml
    • One to four syringes, 100 ml - 140 ml
  • Backlit LCD display
  • Knob locks/unlocks drive block for effortless, drag-free adjustment
  • Simple menu-driven setup:
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
  • Continuous dispense volume display
  • Preset volume control and automatic shut-off
  • Settings can be reviewed or changed during operation
  • Stall detection
  • Choice of unit selection
  • Last settings stored in permanent memory
  • Built-in RS232C interface for computer "daisy chaining" up to 100 pumps
  • TTL interface for foot switch, timer, relay control, outputs for run indicator, valve control
  • Optional multi-step keypad programmable feature  (Model 220P)

Specifications

Pump Type:

Infusion

Max. No. of  Syringes Ten
Syringe Size One to ten syringes,
10
µl to 10 ml
Dimensions 11 x 9 x 5.5 in.
28 x 23 x 14 cm
Weight 9.5  lb (4.3 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep

0.165 micron (1/16 step)
Max Step Rate (1/2 Step) 1600/sec
Min Step Rate 1/100 sec  
Accuracy ¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

22.98 ml/min

25 ml

0.001 ml /h

60.68 ml/min

50 ml

0.001 ml/h

105.8 ml/min

100 ml

0.001 ml /h

212.6 ml/min

250 ml

0.001 ml/h

527.6 ml/min

500 ml

0.001 ml /h

1.06 ml/min

1 ml

0.001 ml/h

2.203 ml/min

3  ml

0.001 ml /h

7.36 ml/min

5 ml

0.001 ml/h

14.33 ml/min

10 ml

0.001 ml /h

20.91 ml/min

20 ml

0.001 ml/h

36.19 ml/min

30 ml

0.001 ml /h

46.49 ml/min

60 ml

0.001 ml/h

70.57  ml/min

140 ml

0.001 ml /h

147 ml/min

back to top


Model 250

Four-Syringe Microdialysis Infusion Pump.  Each syringe can be sized differently and is clamped independently. 

Features

  • Multiple syringe holder
    • Four syringes, 10 ml to 10 ml each
    • Separate clamping accommodates different sizes
    • Syringes may be positioned independently for sequential dispensing by the pusher block.
  • Backlit LCD display
  • Knob locks/unlocks drive block for effortless, drag-free adjustment
  • Simple menu-driven setup:
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
  • Continuous dispense volume display
  • Preset volume control and automatic shut-off
  • Settings can be reviewed or changed during operation
  • Stall detection
  • Choice of unit selection
  • Last settings stored in permanent memory
  • Built-in RS-232C interface for computer "daisy chaining" up to 100 pumps
  • TTL interface for foot switch, timer, relay control, outputs for run indicator, valve control
  • Optional multi-step keypad programmable feature (KDS250P)

Specifications

Pump Type: Infusion
Max. No. of  Syringes Four (Each syringe can be a different size)
Syringe Size 10 ml to 10 ml
Dimensions 11 x 9 x 6 in.
28 x 23 x 15 cm
Weight 9 lb (4 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep

0.165 micron (1/16 step)
Max Step Rate (1/2 Step) 1600/sec
Min Step Rate 1/100 sec. 
Accuracy ¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

22.98 ml/min

25 ml

0.001 ml /h

60.68 ml/min

50 ml

0.001 ml/h

105.8 ml/min

100 ml

0.001 ml /h

212.6 ml/min

250 ml

0.001 ml/h

527.6 ml/min

500 ml

0.001 ml /h

1.06 ml/min

1 ml

0.001 ml/h

2.203 ml/min

3  ml

0.001 ml /h

7.36 ml/min

5 ml

0.001 ml/h

14.33 ml/min

10 ml

0.001 ml /h

20.91 ml/min

back to top


Model 210

The Model 210 offers you more advanced features than any other infusion / withdrawal pump in its price range -- including five operating modes plus independent rate and volume settings for both infusion and withdrawal.

Features

  • Holds two syringes, 10 ml to 140 ml each
  • Backlit LCD display
  • Knob locks/unlocks drive block for effortless, drag-free adjustment
  • Simple menu-driven setup:
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
  • Continuous dispense volume display
  • Preset volume control and automatic shut-off
  • Settings can be reviewed or changed during operation
  • Stall detection
  • Choice of unit selection
  • Last settings stored in permanent memory
  • Built-in RS232C interface for computer "daisy chaining" up to 100 pumps
  • TTL interface for foot switch, timer, relay control, outputs for run indicator, valve control
  • Independent rate and volume settings for infusion and withdrawal
  • Multiple mode selection:
    • Infusion
    • Withdrawal
    • Infusion then withdrawal
    • Withdrawal then infusion
    • Continuous cycle
  • Optional multi-step keypad programmable feature (Model 210P)

Specifications

Pump Type Infusion/Withdrawal
Max. No. of  Syringes Two
Syringe Size 10 ml to 140 ml
Dimensions 11 x 9 x 5.5 in.
28 x 23 x 14 cm
Weight 9 lb (4 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep

0.165 micron (1/16 step)
Max Step Rate (1/2 Step) 1600/sec
Min Step Rate 1 step / 100 sec.
Accuracy ¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

22.98 ml/min

25 ml

0.001 ml/h

60.68 ml/min

50 ml

0.001 ml/h

105.8 ml/min

100 ml

0.001 ml/h

212.6 ml/min

250 ml

0.001 ml/h

527.6 ml/min

500 ml

0.001 ml/h

1.06 ml/min

1 ml

0.001 ml/h

2.203 ml/min

3  ml

0.001 ml/h

7.36 ml/min

5 ml

0.001 ml/h

14.33 ml/min

10 ml

0.001 ml/h

20.91 ml/min

20 ml

0.001 ml/h

36.19 ml/min

30 ml

0.001 ml/h

46.49 ml/min

60 ml

0.001 ml/h

86 ml/min

140 ml

0.001 ml/h

145 ml/min

back to top


Model 230

Ideal for applications requiring multiple syringes, the Model 230 is  an adaptation of the Model 210.  The pump has been modified to hold up to 10 syringes.

Features

  • Multiple syringe holder:
    • One to ten syringes, 10 ml - 10 ml
    • One to six syringes, 20 ml - 60 ml
    • One to four syringes, 100 ml - 140 ml
  • Withdrawal then infusion
  • Backlit LCD display
  • Knob locks/unlocks drive block for effortless, drag-free adjustment
  • Simple menu-driven setup:
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
  • Continuous dispense volume display
  • Preset volume control and automatic shut-off
  • Settings can be reviewed or changed during operation
  • Stall detection
  • Choice of unit selection
  • Last settings stored in permanent memory
  • Built-in RS-232C interface for computer "daisy chaining" up to 100 pumps
  • TTL interface for foot switch, timer, relay control, outputs for run indicator, valve control
  • Independent rate and volume settings for infusion and withdrawal
  • Multiple mode selection:
    • Infusion
    • Withdrawal
    • Infusion then withdrawal
    • Withdrawal then infusion
    • Continuous cycle
  • Optional keypad programmable feature (Model 230P)

Specifications

Pump Type Infusion / Withdrawal
Max. No. of  Syringes One to ten syringes,
10 µl - 10 ml
Syringe Size 10 µl to 140 ml
Dimensions 11 x 9 x 5.5 in.
28 x 23 x 14 cm
Weight 9 lb (4 kg)
Linear Force 40 lb (18 kg)

Advance Per Microstep

0.165 micron (1/16 step)
Max Step Rate (1/2 Step) 1600/sec
Min Step Rate 1 step / 100 sec.
Accuracy ¡Ó  < 1%
Reproducability ¡Ó  0. 1%
Audible Alarm (Optional) **

Flow Rates

Syringe

Minimum

Maximum

10 ml

0.001 ml/h

22.98 ml/min

25 ml

0.001 ml /h

60.68 ml/min

50 ml

0.001 ml/h

105.8 ml/min

100 ml

0.001 ml /h

212.6 ml/min

250 ml

0.001 ml/h

527.6 ml/min

500 ml

0.001 ml /h

1.06 ml/min

1 ml

0.001 ml/h

2.203 ml/min

3  ml

0.001 ml /h

7.36 ml/min

5 ml

0.001 ml/h

14.33 ml/min

10 ml

0.001 ml /h

20.91 ml/min

20 ml

0.001 ml/h

36.19 ml/min

30 ml

0.001 ml /h

46.49 ml/min

60 ml

0.001 ml/h

70.57  ml/min

140 ml

0.001 ml /h

147 ml/min

back to top


Model 310

The Model 310 Reversible Nano Pump is used exclusively with micro syringes.  Small size, remote control and  a rugged mounting arm make it ideal for use with micromanipulator, stereotaxic and other clamping devices.

The single syringe infusion/withdrawal pump consists of a controller and a remote pump head designed to use Hamilton microliter syringes and deliver nanoliter volumes at low flow rates.  The microprocessor based controller uses a bright display and membrane keypad with a simple, menu-prompt system for easy setup.  The pump features preset rate and volume control.   The dispense volume is displayed continuously and the pump shuts off automatically when the preset volume is dispensed.

Features

  • Mini size pump
  • 1 to 100 microliter syringe
  • Simple menu-driven setup with bright display and keypad
    • select syringe size from displayed table
    • dispense volume
    • dispense flow rate
    • infusion or withdrawal
  • Dispense volume is displayed and has automatic shutoff at completion
  • Easy syringe loading with pusher block fast forward/fast reverse feature for rapid adjustments.
  • Last settings stored in memory

Specifications

¡@
Travel: 1/2 step= 6.35 microns with a 10 ml syringe
1/2 step= 1.1 nanoliter
Dimensions: Pump
16.5 x 3 x 4.5 cm (0.16 kg)

Controller
23 x 15.2 x 7.6 cm (2 kg)

Connection Cable
180 cm

Mounting Rod Diameter
0.32 in (8 mm)

Linear Force 1 lb

Flow Rates

Syringe

Minimum

Maximum

Volume

1 ml

0.01 ml/min

1.25 ml/min

0.001 ml

2 ml

0.01 ml /min

2.5 ml/min

0.001 ml

5 ml

0.01 ml/min

6.35  ml/min

0.001 ml

10 ml

0.01 ml /min

13.75  ml/min

0.001 ml