GENESYS
10 UV / Vis Spectrophotometer
Features :
-
Powerful optical design
-
Flexible sample handling
-
Large graphical display
allows easy viewing of instrument conditions and results
-
Cleanable,
chemical-resistant surfaces and rugged design make the
spectrophotometers the ideal choice for harsh laboratory
environments
Specifications:
|
Wavelength Range |
325-1100 nm (GENESYS 10VIS),
190-1100 nm (GENESYS 10UV) |
|
Wavelength Accuracy
|
¡Ó1.0 nm |
|
Wavelength Repeatability
|
¡Ó0.5 nm |
|
Spectral Bandwidth |
5 nm |
|
Photometric Range |
-0.1 to 3.0A; 0.3 to 125%T;
0 to 9999C |
|
Photometric Accuracy |
0.5% of reading, or 0.005A
(whichever is greater) up to 2A |
|
Photometric Readout |
Absorbance, %Transmittance,
Concentration |
|
Detector |
Solid-state detector |
|
Monochromator |
Grating |
|
Noise (peak-to-peak @ 340nm)
|
≤0.001A at 0A; ≤0.002A at 2A
|
|
Drift after warmup
|
≤0.001A/hr
|
|
Stray Light (at 220, 340 &
400 nm) |
≤0.1%T |
|
Display |
LCD, 3.8"x2.8"; 40 col x 20
rows |
|
Supplied interface |
RS-232-C |
|
Supplied Cell Holder |
See below |
|
Software (built-in) |
Built-in: Abs/%T/Conc with
Std/Conc with Factor; Standard Curve; Abs Ratio; Abs
Difference; Kinetics; Survey Scan; 3-Point Net; Multiple
Wavelengths; Performance Verification |
|
Test Storage |
Up to 40 sets of test
parameters |
|
Languages |
English, French, German,
Italian, Spanish |
|
Included with product |
Operator's Manual; Dust
cover |
|
Power Requirements |
100-240V, 50/60Hz |
|
Dimensions |
33cmW x 41cmD x 23.5cmH
(13"W x 16"D x 9"H) |
|
Weight |
19 lbs (8.6 Kg) |
|
|
Ordering information :
P/N
¡@ |
Descriptions
¡@ |
|
33590104 |
GENESYS 10 Vis Spectrophotometer, 325-1100nm range complete with
6 position automatic cell holder, backlit LCD display, RS-232C
interface, manual and dust cover
¡@ |
| 335903P02 |
GENESYS 10 UV
Spectrophotometer, 190-1100nm range complete with 6
position automatic cell holder, backlit LCD display, RS-232C
interface, built-in printer, manual and dust cover |
back to
top
GENESYS 20 UV / Vis
Spectrophotometer
Features :
- Only 10 keys simplify
use
- 2-line, 20 character
LCD readout displays data and gives easily understood instructions
- Clear messages
indicate error conditions
- Four simple steps to
measure absorbance or transmittance
- To run concentration
- just follow the instructions on the display
Specifications:
|
Wavelength Range |
325 to 1100 nm |
|
Wavelength Accuracy
|
¡Ó2.0 nm |
|
Wavelength Repeatability
|
¡Ó0.5 nm |
|
Spectral Bandwidth |
8 nm |
|
Optical System |
Single-beam |
|
Photometric Range |
-0.1 to 2.5A; 0 to 125%T; 0
to 1999C |
|
Photometric Accuracy |
0.003A (from 0 to 0.3A); 1%
of reading (from 0.3A to 2.5A) |
|
Photometric readout |
Abs, %T, Conc, Factor |
|
Lamp Source |
Tungsten Lamp |
|
Detector |
Solid-state detector |
|
Monochromator |
Grating; 1200 lines/mm |
|
Noise (peak-to-peak) |
<0.001A @ 0A; <0.002A @ 2A |
|
Drift |
<0.003/hour |
|
Stray Light (at 340 & 400
nm) |
<0.1%T |
|
Display |
LCD; 20-character, 2-line |
|
Supplied Interface |
RS-232-C; Centronics
parallel |
|
Supplied Cell Holder |
Single-cell for 10-mm
pathlength square and test tube cuvettes |
|
Software |
No PC software available |
|
Test Storage |
One set of parameters in
non-volatile memory |
|
Languages |
English, Spanish, French,
Czech, Portuguese, German |
|
Outputs |
RS-232-C; Centronics
parallel for printer |
|
Included with product |
Dust cover, Operator's
manual; 5 disposable cuvettes |
|
Power Requirements |
100-240V, 50/60Hz |
|
Dimensions |
30cmW x 33cmD x 19cmH
(11.8"W x 13"D x 7.5"H) |
|
Weight |
10 lbs (4.5 Kg) |
|
|
Ordering information :
P/N
¡@ |
Descriptions
¡@ |
|
400104 |
GENESYS 20 Visible
Spectrophotometer, including single position cell holder, 5
disposable cuvettes, manual and dust cover |
back to
top
BioMate 3
Spectrophotometer
Get rapid,
reliable bio analysis results every time with pre-programmed
procedures:
- DNA ratio &
concentration with & without scanning
- Proteins
using Bradford, Lowry, BCA & Biuret reagents
- Direct UV
dsDNA, ssDNA, RNA & oligonucleotides
- Cell growth
- Oligo
calculations
- Plus, all the
capabilities of a standard lab spectrophotometer!
¡@
¡@
Specifications:
| Wavelength
Range |
190 - 1100 nm |
| Wavelength
Accuracy |
¡Ó1.0 nm |
| Wavelength
Repeatability |
¡Ó0.5 nm |
| Spectral
Bandwidth |
5 nm |
| Optical
System |
Split-beam |
| Photometric
Range |
-0.1 to 3.0A 0.3
to 125%T 0 to 9999C |
| Photometric
Accuracy |
0.5% of reading,
or 0.005A, whichever is greater |
| Photometric
Readout |
Absorbance,
%Transmittance, Concentraton |
| Lamp Source |
Xenon Lamp |
| Noise |
0.001A at 0A;
0.002A at 2A (peak-to-peak at 340nm) |
| Drift |
0.001A/hour
after warmup |
| Stray Light |
0.1%T at 220 and
340 nm |
| Display |
LCD; 3.8"x2.8";
40 col x 20 row |
| Supplied
Interface |
RS-232-C |
| Supplied Cell
Holder |
See below |
| Software |
Built-in: DNA
ratio/concentration(with or without scanning); Nucleic Acid (dsDNA,
ssDNA, RNA, oligos) concentration @ 260nm; Protein (Direct UV @
280 & 205nm, Warburg-Christian); Protein Standard Curves
(Bradford, Lowry, BCA, Biuret); Cell Growth; Oligo Calculator (absorptivity,
mol. wt., factor, Tm); Direct Abs, %T, Concentration/Factor,
Concentration/Standard; Standard Curve (up to 15 stds, 7 curve
fits); Absorbance Ratio (with and without Reference Wavelength
Correction); Absorbance Difference (with and without Reference
Wavelength Correction); Kinetics (with and without Reference
Wavelength Correction) with rate curve graph & calculated rate &
activity over user-specified section; Survey Scan with graphical
display, peak/valley, 3-pt net & Area under the Curve; 3-Point
Net; Multiple Wavelengths (up to 31 wavelengths in Abs or Conc);
Performance Verification |
| Test Storage |
Up to 40 sets of
test parameters |
| Languages |
English, French,
German, Italian, Spanish |
| Included with
product |
Operator's
Manual; Dust Cover |
| Power
Requirements |
100-240v, 50/60
Hz |
| Dimensions |
33cmW x 41cmD x
23.5cmH (13"W x 16"D x 9.3"H) |
| Weight |
19 lbs (8.6 Kg) |
| Warranty |
1 year |
Ordering Information
|
Product# |
Description |
|
33590404 |
Biomate 3, Spectrophotometer Includes single cuvette holder,
backlit LCD display, RS232C interface, operator's |
|
335905P04 |
Biomate 3, Spectrophotometer Includes 6-Position Automatic Cuvette
Holder, 335916 Single-Position Cell Holder, backlit LCD display,
RS-232C interface, built-in 335989 Printer, operator's manual,
dust cover |
back to
top
BioMate 5
Spectrophotometer
- Rapid, reliable
nucleic acid and protein analysis results. Every time.

- Pre-programmed
procedures enable even first-time users to perform:
- DNA ratio &
concentration with and without scanning
- Protein standard
curves using Bradford, Lowry, BCA, and Biuret reagents
- Direct UV
concentraitons of dsDNA, ssDNA, RNA & oligonucleotides
- Cell growth
- Oligo calculations
- Plus, all the
capabilities of a standard lab spectrophotometer!
¡@
Specifications:
| Wavelength
Range |
190 to 1100 nm |
| Wavelength
Accuracy |
¡Ó1.0 nm |
| Wavelength
Repeatability |
¡Ó0.2 nm |
| Spectral
Bandwidth |
2 nm |
| Optical
System |
Double-beam;
Quartz-coated |
| Photometric
range |
-0.3 to 3.0A;
-0.1 to 200%T; 0 to 9999C |
| Photometric
Accuracy |
¡Ó0.005A @ 1A |
| Photometric
Readout |
Abs, %T, Conc |
| Lamp Source |
Deuterium Lamp;
Tungsten Lamp |
| Detector |
Solid-state
detector |
| Monochromator |
Grating; Master
Interferometric |
| Noise (RMS) |
<0.001A |
| Drift (after
warm-up) |
<0.001A/hr |
| Stray Light
(@ 220 & 340nm) |
<0.05%T |
| Display |
LCD; ¼VGA
graphics; 4.5" x 3.0" |
| Supplied
Interface |
RS-232-C;
Parallel |
| Supplied Cell
Holder |
7-Position
Water-jacketed Automatic Cell Positioner |
| Software |
Built-in: DNA
ratio/concentration(with or without scanning); Nucleic Acid (dsDNA,
ssDNA, RNA, oligos) concentration @ 260nm; Protein (Direct UV @
280 & 205nm, Warburg-Christian); Protein Standard Curves
(Bradford, Lowry, BCA, Biuret); Cell Growth; Oligo Calculator (absorptivity,
mol. wt., factor, Tm); Direct Abs, %T, Concentration/Factor,
Concentration/Standard; Standard Curve (up to 15 stds, 7 curve
fits); Absorbance Ratio (with and without Reference Wavelength
Correction); Absorbance Difference (with and without Reference
Wavelength Correction); Kinetics (with and without Reference
Wavelength Correction) with rate curve graph & calculated rate &
activity over user-specified section; Scan with graphical display,
peak/valley, 3-pt net & Area under the Curve; 3-Point Net;
Multiple Wavelengths |
| Test Storage |
Up to 30 in
non-volatile memory; 1.44MB floppy disk drive |
| Data Storage |
1.44MB floppy
disk drive |
| Languages |
English, French,
German, Spanish, Italian |
| Outputs |
50-column
internal graphics printer or external printer (See below) |
| Included with
product |
Operator's
Manual; 1 spare tungsten lamp; 1.44MB floppy disk drive |
| Power
Requirements |
100-240V |
| Dimensions |
45.5cmW x
39.5cmD x 21.5cmH (18"W x 15.5"D x 8.5"H) |
| Weight |
22.1 lbs (10 Kg) |
| Warranty |
1 year |
Ordering
Information
|
Product# |
Description |
|
9423BIO1002E |
Biomate 5,
Spectrophotometer with built in printer Includes 9423UV53400E 7
Cell carousel in the sample position and a single cell holder in
the Reference Beam position |
|
9423BIO1202E |
Biomate 5,
Spectrophotometer Includes 9423UV53400E 7 Cell carousel in the
sample position and a single cell holder in the Reference Beam
position |
back to
top
Model M 501, UV / Visible
Scanning Spectrophotometer
- Local Control
Software - All methods are included

- Basic Mode - Measures
Absorbance, %T and Concentration.
- Quantitative -
Up to 10 standard solutions maybe used for a calibration
- Wavelength
Scanning -
- Kinetics - For
time course scanning or reaction rates
- DNA/Protein -
Concentration & DNA purity are calculated
- Multi-Wavelength
- Up to 10 wavelengths
- Performance
Validation - for the GLP compliant laboratory
Specifications :
|
Display |
1/4 VGA 320x240pixels
backlit LCD |
|
Light
sources |
Tungsten-Halogen and
Deuterium |
|
Monochromator |
Littrow type with
1200 lines/mm grating |
|
Detector |
Silicon Photodiode |
|
Wavelength Range |
190 - 1100nm |
|
Wavelength Accuracy |
¡Ó 1nm |
|
Wavelength Resolution |
0.1nm |
|
Wavelength Repeatability |
¡Ó 0.05nm |
|
Noise |
< 0.001A @ 500nm 0A |
|
Zero Drift |
< 0.002A per hour
after warm-up |
|
Baseline Flatness |
¡Ó 0.002A |
|
Bandpass |
4nm (2nm option) |
|
Stray Light (A.S.T.M.) |
<0.1%T @ 220nm and
340nm |
|
Photometric Accuracy |
Better than 1% @
0.5A, 1A, 2A |
|
Photometric Range |
-0.7 to 2.5A, 0 to
200%T, 0 to 9999 Conc |
|
Printer Interface |
Centronic parallel
for eg HP Deskjet |
|
Computer Interface |
Bi-directional
RS232C for PC control |
|
Power Requirements |
110/120V, 220/230V,
50/60 Hz, 110VA |
|
Dimensions |
550 x 420 x 270mm |
|
Weight |
18kg |
back to
top
Model M 400, Diode-Array, Dip
Probe Spectrophotometer
Laboratory
Dip Probes
Using a dip
probe is a new experience. The convenience of simply dipping the probe
into the sample has to be experienced to be fully appreciated. Sample
throughput is amazingly fast with the dip probe and, because the
sample is not consumed, repeat measurements can be made time after
time
Dip Probe
advantages
-
Convenient and rapid sampling
-
Sample
not consumed
-
Sample
not contaminated
-
No
problem with air bubbles
-
No pumps
or flow cells required
-
Interchangeable probe tips offer path lengths from 2 to 50mm
-
Samples
can be measured remote from instrument
-
Ideal for
toxic samples in fume cupboards
-
Measure
direct in large containers
-
Probe can
be 20M from instrument
¡@
Range of
dip probes
Laboratory dip probes
: are offered in a variety of sizes and materials from
silica to stainless steel. The standard lab probe has a barrel
diameter of approx. 6mm and is constructed in stainless steel. It will
tolerate both high temperature and pressure. For really aggressive
samples, we can supply probes in Silica and other materials.
Industrial probes : are available for on-line measurements. The
M400 is an ideal instrument for industrial process control
measurements and offers a wide range of suitable dip probes.
¡@
Cell
Holders
The ambient light rejection properties
of the M400 make possible the use of a cell holder positioned on the
bench-top, or in a fume cupboard or glove box. The cell holder is
offered as an alternative to the dip probe.
-
Fiber
optic cell holders
-
Measurements unaffected by daylight
-
Path
lengths up to 50mm available
-
Remote
measurements at up to 20M from instrument
-
Can be
used in glove boxes, fume cupboards
-
ideal for
toxic or contagious samples
Specifications : ¡@
|
Wavelength Range |
220 to
820nm |
Optical System |
Single beam |
|
Grating |
Concave
holographic |
Detector |
Diode Array |
|
Optical bandwidth |
2nm |
Wavelength accuracy |
+/- 2nm 220-820nm |
|
Wavelength reproducibility |
<+/-
0.05nm |
Integration time |
50 to 2500ms |
|
Absorbance range |
0 to
2.5A |
Photometric accuracy |
<+/- 1%@ 0.5,1,2A |
|
Stray
Light |
<1%T,230-820nm |
Zero
Drift |
<0.003A / hr |
|
Noise |
<0.001A
@ 0A, 220-820nm |
Source
Lamps |
Deuterium, Tungsten-Halogen |
|
Fibre
Optic Cables |
600micron dia. 2M length or Option |
Dip
Probe pathlength options |
2-50mm |
|
Cell
holder accessory with cables |
1mm to
10mm or 1mm to 50mm pathlength |
Weight |
4.5Kg |
|
Dimensions |
350x300x
135mm |
¡@ |
back to
top
¡@
|