Handheld Coating Thickness Gauge

Model 220 is an advanced integrated coating thickness gauge distinguishing by its very compact size, high accuracy, wide measuring range and simplicity of operation. It combines the ferrous F-probe and a data processor in a single unit, automatically computes the thickness of non-magnetic coating (such as paint, plastic, galvanized layers) on a ferrous substrate (such as steel, iron and non-authentic stainless steel), by utilizing the properties of magnetic induction. Both continuous and single measurement modes are available.

@

COATING THICKNESS GAUGE...For All Surfaces & Substrates

@

Model 230 combines the non-ferrous N-probe and a data processor in a robust single unit. It automatically computes the thickness of insulating coatings (such as paint, plastic) on a non-ferrous substrate (such as Aluminum, Copper, Stainless Steel) by utilizing the properties of eddy current. Both continuous and single measurement modes are available.

Model 220 & 230

Specifications:

  • Operating principle:  220 Magnetic induction, 230 Eddy current
  • Measuring range: 0 to 1250 µm
  • Minimum resolution: 1µm
  • Measuring accuracy: mean uncertainty one point calibration (3%H+1) H =nominal value
  • Measuring accuracy: mean uncertainty two point calibration (1-3%H+1) H =nominal value
  • Operating temperature:0 to 45XC
  • Power source:23.6V NiCd batteries
  • Dimensions:1505322mm
  • Weight:120g
  • Optional: printer

  • Advanced Type Coating Thickness Gauges for both Fe or Non-Fe metal, even on Plastic Substrate

    @

    @

    @

    @

    @

    @

    @

    Model 260 is an improved mode1 for CTG-10 Coating Thickness Gauge.260 employs two thickness-measuring methods that are magnetic induction method and induced eddy current method.260 is designed for measuring the thickness of non-magnetic coating layers (aluminum,chrome,copper,ename1,rubber,paint) on magnetic substrate (steel, iron, alloy and magnetic steel) and insulating coating layers (enamel, rubber, paint, plastic) on non-magnetic substrate (copper, aluminum, zinc, tin and etc.)

    Specifications :

    • 2 measuring modes: continuous/single
    • 2 calibrating methods for the gauge, and probe system error correcting by use of basic calibrating method
    • 2 shutdown modes: manual/automatic
    • 495 measured values can be stored
    • 5 statistic values: average, max., min., times of measuring, standard deviation
    • Delete single questionable value in measuring as well as all of the values in memory to perform a new measuring
    • Limits setting and automatically alarm measured values out of limit
    • Analyzing a batch of measuring values via histogram
    • Print measured values, statistic values, limit values and histogram
    • Communicating with PC
    • Low voltage Indication
    • Buzzing Indication in the course of operation
    • Error warning
    • Operation environment:0-40XC ,20%-90%RH,No strong magnetic field
    • Power supply:1/2AA NIMH battery,1.2v,600mAh
    • Dimension:270mm x 86mm x 47mm
    • Weight: approx. 530g

    @