Autoclaves
Safety
Pressure safety device: prevents the opening
of the lid while the chamber is under pressure. Safety over pressure valve:
Prevents the pressure surpassing the set maximum limit. Over pressure cut
out. Disconnects the heater element in the event of surpassing the set
maximum pressure limit. Safety Thermostat. Disconnects power to the heater
element in the event of over temperature or lack of water in the tank.
Safety door closed indicator: Detects and indicates if the lid is in the
correct close position. Thermal protection: The lid has an insulated t hermal
protective cover.
¡@
Features
AISI 304 stainless steel exterior and top.
(model Autester E). Protected epoxy coated steel exterior casing. (model
Autester ST). INCOLOY stainless steel heater element, provides: long life,
corrosion and high temperature resistant. AISI 316.stainless steel
reservoir water tank, lid and lock. Automatic vacuum, purge and dry cycle.
Automatic evacuation of the air in the chamber at the beginning of the
sterilisation cycle. Distilled water reservoir tank to feed the boiler.
External vacuum filter. To obtain the best sterilisation results the chamber
needs to be completely saturated with steam vapour. To guarantee this
condition it is necessary that there are no air pockets that may contain
trapped air in the chamber. It is recommended if any of the following
material is to be sterilised porous materials, fabrics, gauzes, filters,
etc., that a system with a prevacuum and dry options be purchased. All this
autoclaves are equipped with this sistem and automatically purge the air
from the chamber before sterilisation.
¡@
Microprocessor
Functions
The microprocessor controls the running of the
sterilization and drying process using the following pre-selected parameters
set by the operator:
* Sterilization temperature from 105 ¢XC to 134 ¢XC (at 0,2 to 0,2 bar).
Exception, the autoclave Autester ST DRY-PV-25, sterilization temperature up
to 138 ¢XC ( at 2.5 bar).
* Sterilization time from 1minute to 99 minutes.
* Drying time from 1 to 60 minutes.
* Three modes of operation:
- Liquids.
- Solids.
- Solids plus drying.
* The microprocessor monitors and verifies at all times the following
parameters:
- Lid / door is in the correct close position.
- Monitors that the temperature probe is functioning.
- That the temperature and the purge time do not exceed their set limits.
- That the sterilization temperature does not vary more than two degrees
from the set temperature.
Any failure of these parameters is shown as a visible warning on the control
panel, sets off an acoustic warning alarm and automatically disconnects the
heater element.
To guarantee in all circumstances that the system has completed the cycle to
the set time and temperature parameters, the Autester E DRY-PV autoclaves
can be installed with a temperature probe that can be placed within the
culture flask, residual packets etc.
In this way proof that the programmed time and temperature for the run have
been achieved.
When the probe is connected to the controller of the autoclave, it is
automatically recognized by the microprocessor, whereby the real time and
temperature values detected by the probe are displayed and printed.
¡@
Technical Data
Controllable Sterilization Temperature range
from 105 to 134 ¢XC (At 0,2 to 0,2 Bar).
Model ST DRY 25-PV: Controllable sterilization temperature from 105 a 138 ¢XC
(At 0,2 to 2,5 Bar).
Adjustable timer range from 1 to 99 minutes.
Manufactured and certified in accordance with and conforms to the
regulations for services and industry for pressure apparatus and vessels.
Accessories
Baskets
Thermal printer
Pt 100 probe
Software e-interface for Data-Logger.
Data-Logger: Temperature.
AISI 316 stainless steel wire dividers
Detergent "BIO-SEL"
¡@
|
Part No.
|
Drying
|
Capacity litres
|
Ø / Height (usable) cm
|
Height / Width / Depth (exterior)
cm
|
Temp. ºC
|
Reservoir Capacity H2O dest.
|
No. Baskets
|
Power W
|
Dry Power Dry W
|
Weight Kg
|
|
4001414
|
Yes
|
30
|
30 / 40
|
100 / 59 / 48
|
105 to 134
|
17
|
2
|
2800
|
1350
|
87
|
|
4001415
|
Yes
|
75
|
40 / 60
|
109 / 70 / 59
|
105 to 134
|
30
|
2
|
3600
|
2250
|
147
|
|
4001416
|
Yes
|
140
|
50 / 70
|
129 / 89 / 82
|
105 to 134
|
60
|
3
|
7500*
|
4750
|
249
|
¡@
Compact Autoclaves
Continuous pressure purge system for effective sterilization
- No plumbing required
- Automatic operation
- Slow and rapid exhaust models
Purge system eliminates air pockets for uniform penetration of
superheated steam. Just load, set required temperature time, and units
function without further attention. Model 8000D meets EPA criteria and has
both slow and rapid cool down cycles. Both models feature timed drying
cycle, overpressure release, temperature/low water cutoffs and stainless
steel chamber, tray and body. Front mounted controls and gauges. Chamber: 9"
Dia. x 18" Depth. Overall 21x18x14 1/2" high. 220VAC / 50Hz.
Specifications :
¡@
|
|
|
|
|
|
|
|